The class can be instantiated in the following way with and without property name value pairs.
dev=adi.AD9361.Rxdev=adi.AD9361.Rx(Name,Value)
Properties
Unless otherwise indicated, properties are non-tunable, which means you cannot change their values after calling the object. Objects lock when you call them, and the release function unlocks them.
If a property is tunable, you can change its value at any time.
RF center frequency, specified in Hz as a scalar. The default is 2.4e9. This property is tunable.
Baseband sampling rate in Hz, specified as a scalar from 65105 to 61.44e6 samples per second.
RF Bandwidth of front-end analog filter in Hz, specified as a scalar from 200 kHz to 56 MHz.
specified as one of the following: 'slow_attack' — For signals with slowly changing power levels 'fast_attack' — For signals with rapidly changing power levels 'manual' — For setting the gain manually with the Gain property 'hybrid' — For configuring hybrid AGC mode
Channel 0 gain, specified as a scalar from -3 dB to 71 dB. The acceptable minimum and maximum gain setting depends on the center frequency.
specified as one of the following: 'slow_attack' — For signals with slowly changing power levels 'fast_attack' — For signals with rapidly changing power levels 'manual' — For setting the gain manually with the Gain property 'hybrid' — For configuring hybrid AGC mode
Channel 1 gain, specified as a scalar from -3 dB to 71 dB. The acceptable minimum and maximum gain setting depends on the center frequency.
Option to set digital loopback mode, specified as 0, 1 or 2. Allows either to digitally loopback TX data into the RX path or vice versa. Value | Mode --------------------------- 0 | Disable 1 | Digital TX -> Digital RX 2 | RF RX -> RF TX
Option to enable quadrature tracking, specified as true or false. When this property is true, IQ imbalance compensation is applied to the input signal.
Option to enable RF DC tracking, specified as true or false. When this property is true, an RF DC blocking filter is applied to the input signal.
Option to enable baseband DC tracking, specified as true or false. When this property is true, a baseband DC blocking filter is applied to the input signal.
Number of samples per frame, specified as an even positive integer from 2 to 16,777,216. Using values less than 3660 can yield poor performance.
Enable use of custom filter file to set SamplingRate, RFBandwidth, and FIR in datapaths
Path to custom filter file created from filter wizard
Indexs of channels to be enabled. Input should be a [1xN] vector with the indexes of channels to be enabled. Order is irrelevant
Hostname or IP address of remote libIIO deviceHelp for adi.AD9361.Rx/uri is inherited from superclass MATLABSHARED.LIBIIO.BASE
If true, connects to libIIO device during simulationHelp for adi.AD9361.Rx/enIO is inherited from superclass MATLABSHARED.LIBIIO.BASE
Example Usage
%% Rx set up
rx = adi.adi.AD9361.Rx.Rx('uri','ip:analog.local');
rx.CenterFrequency = 1e9;
rx.EnabledChannels = 1;
%% Run
for k=1:10
valid = false;
while ~valid
[out, valid] = rx();
end
end