User Guide

The User Guide is intended for users evaluating Single Pair Ethernet (SPE) devices with the SPE Hub. It explains how to configure the host PC and network for device discovery, and how to use the application’s features to monitor telemetry, control devices, and interact with the network in real time.

Network Topologies

The network topologies section describes a range of supported network configurations for evaluating SPE Hub with evaluation kits, including multidrop, daisy-chain, point-to-point, and switched network topologies.

Network Configuration

Network Connection

The Network Connection page is displayed when SPE Hub is launched. This page serves as the entry point to the application and is used to select the network adapter required for node discovery and communication. SPE Hub starts a local MQTT broker and client bound to the IPv4 address of the selected network adapter. The broker accepts MQTT connections on the standard unsecured port (1883).

An IPv4 address uniquely identifies a node on the network. SPE Hub requires the host PC and all embedded MQTT clients to be configured with unique IPv4 addresses. This allows nodes to be uniquely addressed on the network, enabling reliable routing of MQTT traffic between clients and the broker.

The subnet mask defines which portion of an IPv4 address identifies the network and which portion identifies an individual node. With a subnet mask of 255.255.255.0, addresses sharing the first three octets belong to the same subnet. For example, 192.168.1.10, 192.168.1.20, and 192.168.1.50 are all members of the 192.168.1.0/24 subnet and can communicate directly with one another.

The default gateway is the IPv4 address of a router used to forward traffic outside the local subnet. In most SPE Hub deployments, the default gateway field can be left unconfigured, as the host PC and embedded MQTT clients communicate within the same subnet and do not require traffic to be routed through a gateway.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/network-connection.png

Figure 1 Network Connection

Network Adapter Configuration

The network adapter can be assigned a static IPv4 address using the following method:

  1. Open Control Panel > Network and Internet > Network and Sharing Center.

  2. Select Change adapter settings, then open Properties for the target Ethernet adapter.

  3. Open Internet Protocol Version 4 (TCP/IPv4), select Use the following IP address, and set:

    • IP Address: 192.168.1.200

    • Subnet Mask: 255.255.255.0

  4. Click OK to save and close all dialogs.

Note

The IP address and subnet mask shown above are examples. These settings may need to be adjusted to match the network configuration.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/network-adapter.png

Figure 2 Network Adapter Configuration

Firewall Configuration

When SPE Hub is started for the first time, Windows Defender Firewall may display a security alert requesting network access permissions. Selecting allow access creates a program-based firewall rule for the application.

To accept inbound MQTT connections from embedded clients, Windows Defender Firewall may need to be configured to allow TCP traffic on port 1883. Port 1883 is the standard port for unsecured MQTT and is used by the SPE Hub local MQTT broker service to accept connections from nodes on the network.

A new inbound rule can be created using the Windows Defender Firewall with Advanced Security console. The following steps create a rule that permits inbound TCP traffic on port 1883:

  1. Open Windows Defender Firewall with Advanced Security, select Inbound Rules, and choose New Rule to start the New Inbound Rule Wizard.

  2. Select Port as the rule type, then set the protocol to TCP and specify port 1883 as the local port to allow.

  3. Select Allow the connection, and apply the rule to the network profiles (Domain, Private, and Public) that match the deployment environment.

  4. Provide a descriptive name for the rule, such as SPE Hub MQTT (1883), and finish the wizard to enable it.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/firewall-rule-step1.png

Figure 3 Step 1 - Create a new inbound rule

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/firewall-rule-step2.png

Figure 4 Step 2 - Allow TCP port 1883

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/firewall-rule-step3.png

Figure 5 Step 3 - Allow the connection

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/firewall-rule-step4.png

Figure 6 Step 4 - Name and enable the rule

Application

The Single Pair Ethernet (SPE) Hub is an MQTT-based evaluation platform for SPE products, enabling users to design, evaluate, and validate proof-of-concept applications through real-time device monitoring and control. This section describes the pages and features available once a network connection has been established.

Network Overview

The Network Overview page serves as the main dashboard of the application. Connected MQTT clients are automatically discovered and displayed in the navigation pane when the MQTT service is active. The dashboard provides visibility into network activity and access to monitoring, control, and configuration functions.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/network-overview.png

Figure 7 Network Overview

Temperature Chart [Built-In]

The Temperature Chart provides a real-time visualization of temperature data from all connected nodes. Temperature measurements are displayed using a multi-series line plot, with a dedicated trace for each node. The chart supports configurable x-axis time-window selection, allowing temperature data to be viewed over periods of 10 minutes, 1 hour, 6 hours, 12 hours, or 24 hours. The y-axis can be operated in either Automatic or Manual mode, with manual controls available for configuring the display range and scale step size. Individual node traces can be shown or hidden using the legend controls, allowing users to focus on a specific node or compare behavior across multiple nodes. The chart provides a real-time view of temperature activity across the network, enabling users to monitor sensor behavior, identify missing telemetry, detect node communication issues, and compare measurements between connected nodes.

Network Table

The Network Table provides an operational view of the deployed network, listing all discovered nodes and their current state. Each entry includes a set of actions that allow users to interact directly with a node. These controls support both node identification and network administration, enabling users to activate an onboard LED for physical identification or to kick a client from the MQTT network.

Register Control

The Register Control component provides a mechanism for reading from and writing to device registers across the connected network. The workspace is divided into three complementary components: Access, Queue and History. Register Access enables users to perform individual register read and write transactions on devices associated with a selected node. Register Queue supports the import and execution of predefined command sequences, simplifying repetitive register operations and large-scale device configuration. Register History maintains a chronological record of all register transactions, including request details, execution status and response data.

The Register Queue component accepts CSV files containing one register transaction per row. Each row specifies the target, device, action, address, and optional data value required to perform a register transaction. Imported commands are processed sequentially in the order they appear within the queue. Transactions that encounter validation errors are dropped.

Target

Device

Action

Address

Data

192.168.1.101

adin1140

write

0x010037

0x1234

192.168.1.101

adin1140

read

0x010037

eval-adin1140d1z

adin1140

read

0x010037

adin1140

adin1140

read

0x010037

Note

ADIN1140 and similar devices, the address field is formed by concatenating the MMS and register address. For example, 0x010037 corresponds to MMS 0x01 and Address 0x0037.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/register-control.png

Figure 8 Register Control

MQTT Control

The MQTT Control component provides a centralized interface for MQTT messaging within SPE Hub. It supports manual message publication, periodic message transmission, and monitoring of publish activity.

The publish component provides generic MQTT message transmission capabilities within SPE Hub. It allows users to send predefined MQTT messages directly from the application without requiring an external MQTT client. Messages are loaded from a selected message catalog, where each entry defines a display name, topic, and payload. Users can review the message definition and publish it either as a single transmission or as a recurring transmission.

Interval-based publishing supports configurable transmission periods between 1000 ms and 5000 ms in 500 ms increments. Active interval messages can be paused, resumed, or removed as required. All transmitted messages are recorded in the Publish Activity panel, providing a history of message publication.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/mqtt-control.png

Figure 9 MQTT Control

Node Navigation

The left sidebar serves as a navigator for all discovered nodes. Nodes are grouped by evaluation board type, support search-based filtering, and provide status indicators for quick identification of active and inactive nodes. Selecting a node opens its dedicated page, which is rendered using a board-specific template.

Node Template

Templates define how node data is presented within SPE Hub. As telemetry structures, measurements, and device capabilities vary between evaluation boards, templates provide a flexible mechanism for displaying board-specific information and visualizations. Each supported board type is associated with a dedicated template that maps telemetry and register data to tailored layouts, controls, and graphics. When a node is selected, SPE Hub automatically loads the appropriate template, presenting device information in a consistent, intuitive, and meaningful format across different products.

https://media.githubusercontent.com/media/analogdevicesinc/system-level/main/docs/solutions/application-software/single-pair-ethernet-hub/user-guide/eval-adin1140d1z-node-overview.png

Figure 10 EVAL-ADIN1140D1Z Node Overview