CN0363

Overview

The purpose of this testbench is to validate the SPI interface functionality of the projects/cn0363 reference design.

The entire HDL documentation can be found here CN0363 HDL project.

Block design

The testbench block design includes part of the CN0363 HDL reference design, along with VIPs used for clocking, reset, PS and DDR simulations.

Block diagram

The data path and clock domains are depicted in the below diagram:

CN0363/Testbench block diagram

Configuration parameters and modes

The following parameters of this project can be configured:

  • DATA_WIDTH: defines the SPI data width in bits

  • DATA_DLENGTH: defines the actual data length in bits being transferred

  • NUM_OF_CS: defines the number of chip select lines

  • THREE_WIRE: enables three-wire SPI mode: Options: 0 - Four-wire mode, 1 - Three-wire mode

  • CPOL: defines the SPI clock polarity: Options: 0 - Clock idle state is low, 1 - Clock idle state is high

  • CPHA: defines the SPI clock phase: Options: 0 - Data captured on first edge, 1 - Data captured on second edge

  • CLOCK_DIVIDER: defines the SPI clock divider value

  • NUM_OF_WORDS: defines the number of words per transfer

  • SDO_IDLE_STATE: defines the SDO idle state: Options: 0 - Low, 1 - High

Configuration files

The following configuration file is available:

Configuration mode

Parameters

DATA_WIDTH

DATA_DLENGTH

NUM_OF_CS

THREE_WIRE

CPOL

CPHA

CLOCK_DIVIDER

NUM_OF_WORDS

SDO_IDLE_STATE

cfg1

8

8

2

0

0

1

0

1

0

Tests

The following test program file is available:

Test program

Usage

test_program

Tests the SPI Engine interface and DMA transfer capabilities for CN0363 colorimeter data acquisition.

Available configurations & tests combinations

The test program is compatible with all of the above mentioned configurations.

CPU/Memory interconnect addresses

Below are the CPU/Memory interconnect addresses used in this project:

Instance

Address

axi_intc

0x4120_0000

axi_adc

0x43C0_0000

spi_cn0363_axi_regmap

0x44A0_0000

cn0363_dma

0x44A3_0000

ddr_axi_vip

0x8000_0000

Interrupts

Below are the Programmable Logic interrupts used in this project:

Instance name

HDL

cn0363_dma

13

spi_cn0363

12

Test stimulus

The test program is structured into several tests as follows:

Environment bringup

The steps of the environment bringup are:

  • Create the environment

  • Start the environment

  • Start the clocks

  • Assert the resets

Sanity test

This test verifies basic communication with the AXI register maps by:

  • Reading the VERSION register from the SPI Engine AXI interface

  • Testing SCRATCH register read/write functionality

  • Performing sanity tests on the DMA interface

This ensures that the AXI bus communication is working correctly before proceeding with more complex tests.

FIFO SPI test

The FIFO SPI test verifies simple serial transfers made through the SPI Engine Execution module in FIFO mode.

The steps of this test are:

  • Enable the SPI Engine and configure the Execution module with transfer parameters

  • Set up the interrupt mask to enable SYNC and offload SYNC interrupts

  • Write test data (0xDEAD) to the SDO FIFO

  • Generate a FIFO transaction using SPI Engine commands:

    • Assert chip select

    • Transfer data word

    • De-assert chip select

    • Generate SYNC interrupt

  • Wait for the SYNC interrupt to indicate transfer completion

  • Read back the captured data from the SDI FIFO using the PEEK register

  • Compare the received data with the expected pattern generated by the testbench SDI data generator

Offload SPI test

The Offload SPI test verifies the SPI Engine Offload module functionality for autonomous data acquisition triggered by the util_sigma_delta_spi data_ready signal.

The CN0363 design uses the util_sigma_delta_spi module to detect ADC conversion completion and generate a trigger for the SPI Engine Offload. The testbench simulates the AD7175-2 DOUT/RDY behavior by driving SDI LOW when the SPI bus is idle, allowing util_sigma_delta_spi to naturally detect data_ready and trigger offload transfers.

The steps of this test are:

  • Configure the DMA for data transfer:

    • Enable DMA

    • Set flags (non-cyclic, TLAST enabled, partial reporting enabled)

    • Set transfer length (NUM_OF_TRANSFERS * 4 * 2 bytes)

    • Set destination address in DDR memory

    • Start the DMA transfer

  • Configure the Offload module with SPI Engine command sequence:

    • Configuration command (INST_CFG)

    • Prescaler setting (INST_PRESCALE)

    • Data length configuration (INST_DLENGTH)

    • Assert chip select

    • Read command (INST_RD)

    • De-assert chip select

    • Re-assert chip select (re-arms the 63-clock data_ready counter)

    • SYNC command with ID=2 to generate interrupt

  • Assert CS LOW via FIFO command to bootstrap the first natural trigger

  • Start the offload module to begin autonomous operation

  • Count completed transfers using offload SYNC IRQ events

  • Wait for all transfers (NUM_OF_TRANSFERS) to complete

  • Stop the offload module

  • Verify that:

    • Interrupts were properly generated (IRQ test)

    • Captured SDI data at the offload output matches the expected pattern from the SDI data generator (Offload test)

Note

In the CN0363 design, offload SDI data passes through a processing pipeline (phase_data_sync, HPF, CORDIC demodulator, LPF, DMA sequencer) before reaching DDR memory. Therefore, offload data verification is performed by tapping the SPI Engine Offload module’s SDI output directly, rather than reading back from DDR.

Stop the environment

  • Stop the clocks

Building the testbench

The testbench is built upon ADI’s generic HDL reference design framework. ADI does not distribute compiled files of these projects so they must be built from the sources available here and here, with the specified hierarchy described Set up the Testbenches repository. To get the source you must clone the HDL repository, and then build the project as follows:

Linux/Cygwin/WSL

Example 1

Build all the possible combinations of tests and configurations, using only the command line.

user@analog:~$
cd testbenches/project/cn0363
user@analog:~/testbenches/project/cn0363$
make

Example 2

Build all the possible combinations of tests and configurations, using the Vivado GUI. This command will launch Vivado, will run the simulation and display the waveforms.

user@analog:~$
cd testbenches/project/cn0363
user@analog:~/testbenches/project/cn0363$
make MODE=gui

Example 3

Build a particular combination of test and configuration, using the Vivado GUI. This command will launch Vivado, will run the simulation and display the waveforms.

user@analog:~$
cd testbenches/project/cn0363
user@analog:~/testbenches/project/cn0363$
make MODE=gui CFG=cfg1 TST=test_program

The built projects can be found in the runs folder, where each configuration specific build has its own folder named after the configuration file’s name. Example: if the following command was run for a single configuration in the clean folder (no runs folder available):

make CFG=cfg1

Then the subfolder under runs name will be:

cfg1

Resources

More information

Support

Analog Devices, Inc. will provide limited online support for anyone using the reference design with ADI components via the EngineerZone FPGA reference designs forum.

It should be noted, that the older the tools’ versions and release branches are, the lower the chances to receive support from ADI engineers.