adi.AD9467.Rx
The adi.AD9467.Rx System object is a signal source that can receive complex data from the AD9467.
rx = adi.AD9467.Rx;
rx = adi.AD9467.Rx('uri','ip:192.168.2.1');
Creation
The class can be instantiated in the following way with and without property name value pairs.
dev = adi.AD9467.Rx
dev = adi.AD9467.Rx(Name, Value)
Properties
Unless otherwise indicated, properties are non-tunable, which means you cannot change their values after calling the object. Objects lock when you call them, and the release function unlocks them.
If a property is tunable, you can change its value at any time.
For more information on changing property values, see System Design in MATLAB Using System Objects.
Baseband sampling rate in Hz, specified as a scalar in samples per second. This value read from the hardware after the object is setup.
Select ADC test mode. Options are: ‘off’ ‘midscale_short’ ‘pos_fullscale’ ‘neg_fullscale’ ‘checkerboard’ ‘pn_long’ ‘pn_short’ ‘one_zero_toggle’
FilterHighPass3dbFrequency
Scale received data. Possible options are: 0.030517 0.032043 0.033569 0.035095 0.036621 0.038146
Number of samples per frame, specified as an even positive integer from 2 to 16,777,216. Using values less than 3660 can yield poor performance.Help for adi.AD9467.Rx/SamplesPerFrame is inherited from superclass adi.AD9467.Base
Indexs of channels to be enabled. Input should be a [1xN] vector with the indexes of channels to be enabled. Order is irrelevant
Hostname or IP address of remote libIIO deviceHelp for adi.AD9467.Rx/uri is inherited from superclass matlabshared.libiio.base
Example Usage
%% Rx set up
rx = adi.AD9467.Rx('uri','ip:analog.local');
rx.SamplesPerFrame = 2^14;
rx.EnabledChannels = 1;
%% Run
for k=1:10
valid = false;
while ~valid
[out, valid] = rx();
end
end
%% Cleanup
release(rx)