PlutoSDR/M2k boot magic explained

There are few different use cases, and methods to locally (USB/Serial), or remotely (USB/Network) to reboot a Pluto/M2k.

Pluto/M2k was designed never to have to be rebooted - but software bugs happen. Before you reboot things - try to ask yourself “why”, what went wrong, how do I reproduce, and how can I file a bug report that will help someone debug.

Custom u-boot environment variables

There are a set of custom u-boot environmental variables used during boot, which either are set dynamically by custom u-boot commands, or are imported from an additional protected u-boot environment or are part of the regular SPI u-boot environment but are used to control the runtime behavior.

Hardware Revision Handling

The PlutoSDR or M2k firmware (FIT image) supports multiple HW revisions. It’s being done reading a voltage divider which is unique for a given HW revision using the on chip XADC. This voltage is then mapped into 10 possible values which are then set in the fit_config environmental variable. Values are in the form of config@%d where %d is in the range from 0..9. This variable is then being used to load the corresponding FIT config which is right now only a dedicated device tree, however when necessary can be extended to also load a different bitfile.

The adi_hwref command will set fit_config and for Pluto Rev.A it will additionally set the PlutoRevA variable.

variable

comment

fit_config

config@ number

PlutoRevA

set only for Rev.A

Device tree patching

During factory calibration the onboard TCXO reference frequency is measured and the actual reference clock frequency is stored in an additional protected SPI environment which is imported during boot. Later on this value is used to patch the device tree property clock-frequency in the /clocks/clock@0 path. This step can be skipped by the user when setting the ad936x_skip_ext_refclk variable. This allows for custom reference clock frequency set in the regular device tree.

variable

device tree destination

Comment

ad936x_ext_refclk

/clocks/clock@0 clock-frequency

Skip this by setting the ad936x_skip_ext_refclk variable

model

/model

Model string

attr_name

/amba/spi@e0006000/ad9361-phy@0 ${attr_name} ${attr_val}

attr_val

/amba/spi@e0006000/ad9361-phy@0 ${attr_name} ${attr_val}

Set during DFU update

The DFU altsetting of the DFU interface is stored in the dfu_alt_num variable and the transfers size is stored in the filesize variable.

variable

comment

dfu_alt_num

altsetting of the DFU interface in progress

filesize

filesize of the transferred firmware image

Miscellaneous

variable

comment

uboot-version

u-boot version string set by the envversion command

Examples

What this means is to change any of these, log into your pluto sdr (over network or serial), and do this as root:

  • If you want to replace the 40 MHz oscillator, and insert a 20 MHz (20000000 Hz) clock:

    # fw_setenv ad936x_ext_refclk "<20000000>"
    

    The quotes need to be there to escape the <>, which need to be there since this goes into device tree.

  • If you have a AD9364 inside your PlutoSDR

    # fw_setenv attr_name compatible
    
    # fw_setenv attr_val ad9364
    
  • If you have a standard Zynq 7010 (not the special single core version)

    # fw_setenv maxcpus
    
  • If you want to tweak your default XO correction rather than 40 MHz, you have determined at a stable temp it is 39,999,764 Hz:

    # fw_setenv xo_correction 39999764
    

All Environmental Settings Table

This table applies for firmware releases v0.32 onward.

Control

Default

min FW Version

HW Rev

name

value

configuration meaning

Tuning Range

Y

All

B/C

attr_name / attr_val

<blank> / blank

tuning range is 325 - 3800 MHz, mode is 1r1t or 2r2t

All

B/C

attr_name / attr_val

compatible / ad9364

tuning range is 70 - 6000 MHz, mode is 1r1t only

0.32

C

attr_name / attr_val

compatible / ad9361

tuning range is 70 - 6000 MHz, mode is 1r1t or 2r2t

Number of channels

Y

0.32

B/C

mode

1r1t

1 Rx, 1 Tx, 61.44 MSPS max data rate

0.32

C

mode

2r2t

2 Rx, 2 Tx, 30.72 MSPS max data rate (requires ad9363 or AD9361 settings)

Reference Clock in

Y

0.32

B/C

refclk_source

internal

Internal Reference Clock, ad936x_ext_refclk_override holds frequency in Hz

0.32

C

refclk_source

external

Reference Clock on u.FL is used, ad936x_ext_refclk_override holds frequency in Hz

Reference Clock Value

Y

0.32

B/C

ad936x_ext_refclk

<40000000>

40 MHz, is the measured value determined at production test and should not be modified

0.32

C

ad936x_ext_refclk_override

<any>

Actual clock setting in Hz, 10 - 80 MHz, resolution is in Hz

SPI Controls

Y

0.32

C

cs_gpio

<any>

GPIO chip select for use with axi spi